Vaisala DRYCAP DMT340 SERIES Guide de l'utilisateur Page 48

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 191
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 47
User's Guide _______________________________________________________________________
46 ___________________________________________________________________ M210704EN-G
Leak Screw Installation
When the probe cannot be installed directly in the pressurized process or
process pipe, a leak screw installation can be used.
In this installation method, you must install the DMT348 probe using a
fitting body with leak screw, see Figure 27 on page 41. A small sample
flow from the process goes through the probe and via the leak screw out
to atmospheric pressure enabling a fast response time although the probe
is not installed in the process.
0503-036
Figure 31 Probe in Leak Screw Installation
The numbers refer to Figure 31 above:
1
=
Probe
2
=
Filter
3
=
Ball of the ball valve
4
=
Leak screw
Vue de la page 47