Note: Hectopascal (hPa) is the barometric pressure unit
recommended by WMO and also accepted by ISO.
1 hPa = 1 mbar
Barometric Pressure
Operating Range
Pressure range 500...1100 hPa
Temperature range
operating -40...+140°F (-40...+60 °C)
with local display 32...+140°F (0...+60 °C)
storage -76...+140°F (-60...+60 °C)
with local display -4...+140°F (-20...+60 °C)
Humidity range non-condensing
Accuracy
Class A Class B
Linearity* ±0.05 hPa ±0.10 hPa
Hysteresis* ±0.03 hPa ±0.03 hPa
Repeatability* ±0.03 hPa ±0.03 hPa
Calibration uncertainty** ± 0.07 hPa ±0.15 hPa
Accuracy at 68°F (+20 °C***+) ± 0.10 hPa ±0.20 hPa
Temperature dependence**** ±0.1 hPa
Total accuracy including one year drift
Class A ±0.15 hPa Class B ±0.25 hPa
Long-term stability ±0.1 hPa/year
Response time (one sensor 100% response)
Class A 2 s Class B 1 s
* Defined as ±2 standard deviation limits of end-point non-
linearity, hysteresis error or repeatability error.
** Defined as ±2 standard deviation limits of inaccuracy of
the working standard including traceability to NIST.
*** Defined as the root sum of the squares (RSS) of end-point
non-linearity, hysteresis error, repeatability error and
calibration uncertainty at room temperature.
**** Defined at ±2 standard deviation limits of temperature
dependence over the operating temperature range.
Relative Humidity & Temperature
(HMP 45A-P)
Measurement Range 0...100 %RH
Accuracy at +20 °C (including non-linearity and hysteresis)
against factory references ±1 %RH
field calibration against references ±2 %RH (0...90 %RH)
±3 %RH (90...100 %RH)
Typical long-term stability better than 1 %RH per year
Temperature dependence ±0.03 %RH/°F (±0.05 %RH/°C)
Response time (90%) at +20 °C 15 sec. with membrane filter
Sensor HUMICAP® 180
Measurement Range -40...+140 °F (-40...+60 °C)
Accuracy
Temp Accuracy
-40°F (-40 °C) ±0.9°F (±0.5 °C)
68°F (20 °C) ±0.4°F (±0.2 °C)
140°F (+60 °C) ±0.7°F (±0.4 °C)
Temperature sensor HMP 45 A-P Pt 1000 IEC 751 1/3 Class B
HMP 45D Pt 100 IEC 751 1/3 Class B
Cable length
HMP 45 A-P 20m with binder connector
HMP 45 D 3.5m, hard-wired
Pt100 Sensor Head
Measurement Range -40...+140 °F (-40...+60 °C)
Accuracy ±0.4°F (±0.2°C)
Sensor Pt 100 IEC 751 1/4 Class B
Cable length 2m
General
Supply voltage 10...30 VDC reverse polarity
protected
Supply voltage sensitivity negligible
Current consumption
operation mode less than 30 mA
with local display less than 30 mA (without back light)
less than 50 mA (with back light)
hardware shutdown mode less than 0.1 mA
Serial I/O RS 232C full duplex or
bidirectional TTL level or
RS 485/422 half duplex two-wire
code ASCII
parity none, even, odd
data bits 7 or 8
stop bits 1 or 2
Pressure units hPa, mbar, kPa, Pa, inHg,
mmH20, mmHg, torr, psia
Humidity units %RH
Temperature units °F, °C
Baud rates 300, 600, 1200, 2400, 4800, 9600
Resolution
class A 0.01 hPa
class B 0.1 hPa
Settling time at power-up (one sensor)
class A 5 s
class B 4 s
Acceleration sensitivity negligible
Pressure connector M5 (10-32) internal thread
Pressure fitting barbed fitting for 1/8" I.D. tubing
Maximum pressure limit 5000 hPa abs.
Electrical connector female 9-pin subD
Housing
body epoxy painted aluminum
RH&T probe ABC plastic
Weight
depending on selected probe 2.3/1.3/1.1 kg
Specifications subject to change without prior notice.
BAROCAP® is a registered trademark of Vaisala, Inc.
Factory setting
TECHNICAL DATA - PTU 200
Dimensions in mm
cable length 2, 5, or 10 m
PTU 200
BACK to
Table of
Contents
To INDEX
PTU 200
Price List