Résumé du contenu

Page 1 - USER'S GUIDE

USER'S GUIDE Vaisala HUMICAP® Humidity and Temperature TransmittersHMD60U/Y U301EN11

Page 2

HMD60U/Y TransmittersOperating Manual U301en-1.16 1997-07-313.5 Electronics10528HM18941HMGLANDS LIDSCREW TERMINALSCREWSMEMBRANE FILTER part no. 17039

Page 3 - Contents

HMD60U/Y TransmittersU301en-1.1 Operating Manual1997-07-31 74. CALIBRATION4.1 One-point humidity calibrationThe accuracy is recommended to be checked

Page 4

HMD60U/Y TransmittersOperating Manual U301en-1.18 1997-07-314.3 Calibration tableTemperature °C 15 20 25 30 35°F 59 68 77 86 95LiCl %RH *) 11.3 11.3 1

Page 5 - 1. PRODUCT DESCRIPTION

HMD60U/Y TransmittersU301en-1.1 Operating Manual1997-07-31 96. TECHNICAL DATA6.1 Relative humidityMeasurement range 0...100 %RHAccuracy at +20 °C:10 4

Page 6 - 2 1997-07-31

HMD60U/Y TransmittersOperating Manual U301en-1.110 1997-07-316.3 GeneralSupply voltage 10...35 VDC (RL= 0Ω)20...35 VDC (RL=500Ω)Output signal 4...20 m

Page 7 - 3. INSTALLATION

HMD60U/Y TransmittersU301en-1.1 Operating Manual1997-07-31 116.4 Electromagnetic compatibilityThe emission and immunity tests have been performed acco

Page 11 - 4. CALIBRATION

PUBLISHED BY Vaisala Oyj Phone (int.): +358 9 8949 1 P.O. Box 26 Fax: +358 9 8949 2227 FIN-00421 Helsinki Finland Visit our Internet pages at ht

Page 12 - 5. MAINTENANCE

HMD60U/Y TransmittersU301en-1.1 Operating Manual1997-07-31 iContents1. PRODUCT DESCRIPTION ...

Page 13 - 6. TECHNICAL DATA

HMD60U/Y TransmittersOperating Manual U301en-1.1ii 1997-07-31This page intentionally left blank.

Page 14 - 10 1997-07-31

HMD60U/Y TransmittersU301en-1.1 Operating Manual1997-07-31 11. PRODUCT DESCRIPTIONThe HMD60 transmitters are duct mounted two-wire transmitters for th

Page 15 - U301en-1.1 Operating Manual

HMD60U/Y TransmittersOperating Manual U301en-1.12 1997-07-312. TO BE NOTED WHEN MEASURING HUMIDITYIn the measurement of humidity and especially in cal

Page 16

HMD60U/Y TransmittersU301en-1.1 Operating Manual1997-07-31 33. INSTALLATION3.1 Selecting the place of installationSelect a place that gives a true pic

Page 17

HMD60U/Y TransmittersOperating Manual U301en-1.14 1997-07-313.3 GroundingOpen the lid and mount the cable bushing set 18941HM. Do the groundingaccordi

Page 18

HMD60U/Y TransmittersU301en-1.1 Operating Manual1997-07-31 53.4 Electrical connectionsConnect the signal cables to a removeable 5-pole screw connector