Chapter 3 _______________________________________________________________ Installation
VAISALA_______________________________________________________________________ 31
Power Supply Terminal Blocks
Conducting Off-Line Test
1. Turn on the AC power to the wind sensor in your system (system
power distribution).
2. Turn on the power switch in the power supply.
3. Connect a laptop to the TEST connector in the power supply with
an RS-232 cable. Run the Diagnostics Program on the laptop.
Choose the option that connects the sensor to the laptop with the
system disconnected.
4. Issue the WA command. The sensor must respond with a P status.
Table 1 Terminal Block 1
TB1
Terminal Name Description
1 12.6 V_H1 12.6 VAC transformer, line 1
2 12.6 V_CT 12.6 VAC transformer, center tap
3 12.6 V_H2 12.6 VAC transformer, line 2
4 36 V_H1A 24 VAC transformer, line A
5 36 V_H2A 24 VAC transformer, return A
6 36 V_H1B 24 VAC transformer, line B (internally connected to 36 V_H1A)
7 36 V_H2B 24 VAC tansformer, return B (internally connected to 36
V_H2A)
Table 2 Terminal Block 2
TB2
Terminal Name Description
1 TOP_HEAT Top heater line, switched 24 VAC
2 ENCLOSUREHEATB Two of two enclosure heater lines, switched 24 VAC
3 ENCLOSUREHEATA One of two enclosure heater lines, switched 24 VAC
4 RETURN_36VAC_B Heater return, ground at sensor
5 RETURN_36VAC_A Heater return, ground at sensor
6 TOP_CTRL To heater control, >+3 V = ON
7 ENLOSURE_CTRL Enclosure heater control, >+3 V = ON
8 SENSOR+12V +12 VDC to sensor
9 SENSOR_TXD Connect to sensor TX data line
10 SENSOR_RXD Connect to sensor RX data line
11 GND (12V Common) Ground return from sensor
12 GND (RS232 Common) Connect to sensor cable shield