138
TOP VIEW
240 (9.4)
120 (4.7)
32 (1.3)
40 (1.6)
127 (5)
Technical Data, Dimensions
BAROCAP®, HUMICAP®, RAINCAP®, THERMOCAP® and
WINDCAP® are registered trademarks of Vaisala.
Specifications subject to change without prior notice.
© Vaisala Oyj
Mounting kit (optional)
General
Self-diagnostic separate supervision message,
unit/status fields to validate
measurement quality
Start-up automatic, <10 seconds from
power on to the first valid output
Communication protocols SDI-12 v1.3, ASCII automatic & polled,
NMEA-0183 v3.0 with query option
Port H/W SDI-12, RS-232, RS-485, RS-422
Baud rate 1 200, 2 400...115 200
Operating temperature -52…+60 °C (-60...+140 °F)
Storage temperature -60…+70 °C (-76...+158 °F)
Operating humidity 0...100 %RH
Dimensions
Height 240 mm (9.4 in)
Diameter 120 mm (4.7 in)
Weight 650 g (1.43 lbs)
Power Supply
Input Voltage 5...30 VDC
Power consumption on average
minimum 0.07 mA @ 12 VDC (in SDI-12 mode)
maximum 13 mA @ 30 VDC (with continuous
measurement of all parameters)
typical 3 mA @ 12 VDC (with default measuring intervals)
Heating voltage options: DC, AC, full wave rectified AC
recommended ranges 12 VDC ±20%, 1.1 A max.
24 VDC ±20%, 0.6 A max.
68 V
p-p
±20% (AC), 0.6 A
rms
max.
34 V
p
±20% (f/w rect. AC), 0.6 A
rms
max.
absolute max 30 VDC
84 V
p-p
(AC)
42 V
p
(f/w rect. AC)
Electromagnetic compatibility
Complies with EMC standard: EN61326-1:1997 + Am1:1998 + Am2:2001;
Generic Environment.
Dimensions
Dimensions in mm (inches).
WEATHER_2005_GLOBAL.PMD 7.12.2004, 7:40138