Vaisala MMT310 Manuel d'utilisateur Page 78

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 81
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 77
User's Guide _______________________________________________________________________
78 ___________________________________________________________________ M210474EN-C
PPM Calculation Setting
Calculation Setting (Calculation Model
with Average Coefficients)
Give the OIL ON command when you are measuring moisture in oil and
want to have ppm output.
Syntax: OIL x <cr>
x= ON/OFF
Example:
>oil on
Oil ppm : ON
>oil
Oil ppm : ON
Oil[0] : -1.66269994E+03
Oil[1] : 7.36999989E+00
>
Changing the Calculation Coefficients
(Calculation Model with Oil Specific
Coefficients)
1. Press the blue adjustment button on the MMT310 board (see Figure
15 on page 56) to enable feeding of coefficients.
2. Give the OIL command.
OIL <cr>
3. Type the first coefficient after the question mark and press
ENTER..
4. Type the second coefficient after the second question mark and
press ENTER.
5. Reset the transmitter by giving the RESET command. Turn the
power off and back on to return the transmitter to the normal mode.
Example:
>oil
Oil ppm : ON
Oil[0] : -1.66269994E+03 ?
Oil[1] : 7.36999989E+00 ?
>
Vue de la page 77
1 2 ... 73 74 75 76 77 78 79 80 81

Commentaires sur ces manuels

Pas de commentaire