Vaisala WINDCAP WS425 Guide de l'utilisateur Page 26

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 221
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 25
User's Guide ______________________________________________________________________
Heating
Ordering option 3, Heating, defines if the sensor is equipped with
extra heating for demanding environmental conditions. Option 4
providing full sensor heating is best suited for most demanding
environments. Note that power consumption requirement depends
on the selected heating option.
Table 7 Heating
Option
Heating
1
Non-heated
2
Heated transducers (Min. 30 W power supply is needed)
3
Heated transducers and arms (Min. 200 W needed)
4
Heated transducers, arms, and body (Min. 350 W needed)
Digital Communication Interface
Ordering option 4, Digital Communication Interface, defines the
serial line physical interface. Four different standard
communication interfaces are available.
Table 8 Digital Communication Interface
Option
Hardware Interface
A
RS-485 isolated (1 pair)
B
RS-422 isolated
C
RS-232 isolated
D
SDI-12 isolated
24 ___________________________________________________________________ M211095EN-E
Vue de la page 25
1 2 ... 21 22 23 24 25 26 27 28 29 30 31 ... 220 221

Commentaires sur ces manuels

Pas de commentaire