HMP230 SERIES
Appendix 1: Serial commands M210225en-B
80
SERIAL COMMANDS
1. ANALOGUE OUTPUT COMMANDS .................................................................................. 81
AMODE Setting the analogue outputs.................................................................... 81
ASEL Scaling the analogue outputs ................................................................... 82
ASCL Scaling the analogue outputs ................................................................... 83
2. CALIBRATION COMMANDS ............................................................................................. 84
CRH Relative humidity calibration ................................................................... 84
FCRH Relative humidity calibration after sensor change..................................... 84
CT Temperature calibration .......................................................................... 85
ACAL Calibrating the analogue outputs.............................................................. 86
L Outputting linear correction coefficients .................................................. 86
LI Entering linear correction coefficients ..................................................... 86
3. OUTPUT VIA THE SERIAL BUS........................................................................................ 87
R Starting the measurement output ............................................................ 87
S Stopping the measurement output .......................................................... 87
SEND Outputting a reading once........................................................................ 88
DSEND Outputting readings of all connected transmitters once ............................ 88
ERRS Outputting error messages....................................................................... 88
ECHO Turning the serial interface echo ON/OFF................................................ 89
INTV Setting the output interval for the RUN state ........................................... 89
FORM Setting the output format.......................................................................... 90
FTIME Adding time to output ............................................................................... 91
FDATE Adding date to output............................................................................... 92
SERI Serial bus settings .................................................................................. 92
UNIT Selecting the output units........................................................................ 93
ADDR Setting the transmitter address ................................................................ 94
FROST Setting the calculation mode .................................................................... 94
RESET Resetting the transmitter.......................................................................... 94
3.1 Operation modes .................................................................................................. 95
SMODE Setting the serial interface ....................................................................... 95
OPEN & CLOSE ..................................................................................................... 95
4. OTHERS ............................................................................................................................ 97
ITEST Testing the analogue outputs ................................................................... 97
FILT Setting the averaging time ...................................................................... 98
PRES Setting the pressure for pressure compensation of the HUMICAP
sensor
and for mixing ratio, wet bulb temperature and enthalpy calculations ....... 98
XPRES Setting the pressure for pressure compensation of the HUMICAP
sensor
and mixing ratio, wet bulb temperature and enthalpy calculations
temporarily............................................................................................... 99
CDATE Entering calibration date .......................................................................... 99
DATE Setting the date ......................................................................................100
TIME Setting the time.......................................................................................101
VERS Name and version of the programme ......................................................101
? Outputting the transmitter settings .........................................................101
?? Outputting the transmitter settings also in POLL mode...........................102
The commands function as described when the serial interface is in full-
duplex mode and echo is on. All commands except FORM can be given in
either capital or small letters. In the commands <cr> means carriage return,
<lf> line feed and <ht> horizontal tabulation.