Vaisala WINDCAP WS425 Guide de l'utilisateur Page 64

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 136
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 63
USER'S GUIDE____________________________________________________________________
62 __________________________________________________________________ M211095EN-C
Digital Communication Interface
COM2 is a flexible digital communication interface that is preconfigured
according to your order. The available options are:
- RS-232
- RS-485
- RS-422
- SDI-12
COM1 is a fixed RS-485 communication interface intended to be used as
a service port.
Regardless of the factory configuration, COM2 interface type can be
changed by using terminal software. See com2_interf in Appendix D on
page 129.
For information on wiring, see section Wiring on page 52.
Digital Communication Profiles
The Digital Communication Profile is used to preconfigure WMT700
according to your order at the factory. Depending on the preconfigured
communication profile, the default settings of the following parameters
may vary:
- Communication protocols
- Communication parameters
See Appendix C on page 127 for the factory defaults for all
communication profiles. The preconfigured com
munication profiles are:
- WMT700
- ROSA - MES12
- WS425 - ASCII
- WS425 - NMEA Extended (version 0183)
- WS425 - SDI-12 (version 1.3)
- WS425 - ASOS
The WMT700 profile is recommended for normal operation. The profile
offers a wide range of predefined and user-configurable data message
formats and it is specifically developed for WMT700. For information on
user-configurable data messages, see section Parameters Handling
Comm
ands on page 74. For information on predefined data messages,
see section Data Messages on page 92.
Vue de la page 63
1 2 ... 59 60 61 62 63 64 65 66 67 68 69 ... 135 136

Commentaires sur ces manuels

Pas de commentaire