Vaisala WMS302 Guide de l'utilisateur Page 217

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 262
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 216
Chapter 8 ____________________________________________________________ Technical Data
VAISALA______________________________________________________________________ 215
Channel B can be used either in the RS-485 mode or in the RS-232
mode. In 2-wire RS-485, both transmitted and received data is sent via
this channel. In 4-wire RS-485, this channel can either transmit or
receive depending on the configuration.
Figure 156 on page 214 provides a schematic wiring diagram for the
dual RS-485 connection, the dual 2-wire connection utilizing both
channels. The correct jumper settings for the channel B are listed in
Table 38 on page 215. The jumpers are located on the module as
illustrated in Figure 157 on page 215.
0201-049
Figure 157 DSI486 Default Jumper Locations
Table 38 The Jumper Settings for Channel B in the RS-485
Mode
Jumper Connected
Pins
Function
X3 1-2 Sets the RS-485 mode active for the channel
B.
3-4
X6 1-2
X5 1-2 The line terminating resistor is in use with RS-
485.
Vue de la page 216
1 2 ... 212 213 214 215 216 217 218 219 220 221 222 ... 261 262

Commentaires sur ces manuels

Pas de commentaire