Vaisala WMS302 Guide de l'utilisateur Page 222

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 262
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 221
User's Guide ______________________________________________________________________
220 __________________________________________________________________M210630EN-B
Soil Moisture Sensor
Soil moisture sensor uses one analog channel of the logger. You should
connect the cutted sensor cable to the appropriate channel.
1. Pull the sensor cable close to the logger enclosure. Cut the cable to
a proper length. Thread the cable through the connector parts in the
indicated order 1-2-3-4. See Figure 163 on page 220.
9806-015
Figure 163 Assembling the Connector
2. Strip the sensor cable wires and connect them to connector
terminals according to Table 41 on page 220. Make sure that the
spring of the lead-in connector is in good contact with the shield.
Assemble the connector and connect it to the appropriate connector
of the logger enclosure.
Table 41 Cable Pins of Soil Moisture Sensor ML2x
Pin Number Wire Color Signal
1 Red Supply, +
2 Yellow Signal HI
3 Blue Supply, -
4 Green Signal LO
Vue de la page 221
1 2 ... 217 218 219 220 221 222 223 224 225 226 227 ... 261 262

Commentaires sur ces manuels