Chapter 7 __________________________________________________ Getting the Data Messages
VAISALA_______________________________________________________________________ 79
Automatic Mode
When automatic ASCII protocol is selected the transmitter sends data
messages at user configurable update intervals. The message structure
is same as with data query commands aR1, aR2, aR3 and aR5. You can
choose an individual update interval for each sensor, see Chapter 8,
Sensor and Data Message Settings, on page 107, sections Changing the
Settings.
Example:
0R1,Dm=027D,Sm=0.1M<cr><lf>
0R2,Ta=74.6F,Ua=14.7P,Pa=1012.9H<cr><lf>
0R3,Rc=0.10M,Rd=2380s,Ri=0.0M,Hc=0.0M,Hd=0s,
Hi=0.0M<cr><lf>
0R5,Th=76.1F,Vh=11.5N,Vs=11.5V,Vr=3.510V<cr><lf>
Example (with CRC):
0r1,Sn=0.1M,Sm=0.1M,Sx=0.1MGOG<cr><lf>
0r2,Ta=22.7C,Ua=55.5P,Pa=1004.7H@Fn<cr><lf>
0r3,Rc=0.00M,Rd=0s,Ri=0.0MIlm<cr><lf>
0r5,Th=25.0C,Vh=10.6#,Vs=10.8V,Vr=3.369VO]T<cr><lf>
Automatic Composite Data
Message (aR0)
When automatic composite data messaging is selected, the transmitter
sends composite data messages at user configurable intervals. The
message structure is the same as with the composite data query
command aR0 and contains a user configurable set of wind, pressure,
temperature, humidity, precipitation and supervisor data.
NOTE
Stop the automatic output by changing the communication protocol to
polled mode (aXU,M=P).
Polling commands aR1, aR2, aR3, and aR5 can be used also in ASCII
automatic protocol for requesting data.