Vaisala WXT520 Guide de l'utilisateur Page 72

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 171
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 71
User’s Guide ______________________________________________________________________
70 __________________________________________________________________ M210906EN-C
ASCII Protocol
This section presents the data commands and data message formats for
the ASCII communication protocols.
Abbreviations and Units
For changing the units, see Chapter 8, Sensor and Data Message
Settings, on page 107.
Table 6 Abbreviations and Units
Abbreviation Name Unit
Status
1
1. The letters in the status field indicate the Unit, the # character indicates invalid data.
Sn Wind speed minimum m/s, km/h, mph, knots #,M, K, S, N
Sm Wind speed average m/s, km/h, mph, knots #,M, K, S, N
Sx Wind speed maximum m/s, km/h, mph, knots #,M, K, S, N
Dn Wind direction minimum deg #, D
Dm Wind direction average deg #, D
Dx Wind direction
maximum
deg #, D
Pa Air pressure hPa, Pa, bar, mmHg,
inHg
#, H, P, B, M, I
Ta Air temperature °C, °F #, C, F
Tp Internal temperature °C, °F #, C, F
Ua Relative humidity %RH #, P
Rc Rain accumulation mm, in #, M, I
Rd Rain duration s #, S
Ri Rain intensity mm/h, in/h #, M, I
Rp Rain peak intensity mm/h, in/h #, M, I
Hc Hail accumulation
hits/cm
2
, hits/in
2
, hits
#, M, I, H
Hd Hail duration s #, S
Hi Hail intensity
hits/cm
2
h, hits/in
2
h, hits/
h
#, M, I, H
Hp Hail peak intensity
hits/cm
2
h, hits/in
2
h, hits/
h
#, M, I, H
Th Heating temperature °C, °F #, C, F
Vh Heating voltage V
#, N, V, W, F
2
2. For heating # = heating option is not available (has not been ordered). N = heating option is available
but have been disabled by user or the heating temperature is over the high control limit. V = heating is
on at 50% duty cycle and the heating temperature is between the high and middle control limits. W =
heating is on at 100% duty cycle and the heating temperature is between the low and middle control
limits. F = heating is on at 50% duty cycle and the heating temperature is below the low control limit.
Vs Supply voltage V V
Vr 3.5 V ref. voltage V V
Id Information field alphanumeric
Vue de la page 71
1 2 ... 67 68 69 70 71 72 73 74 75 76 77 ... 170 171

Commentaires sur ces manuels

Pas de commentaire