Vaisala WXT520 Guide de l'utilisateur Page 32

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 171
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 31
User’s Guide ______________________________________________________________________
30 __________________________________________________________________ M210906EN-C
0806-010
Figure 9 Heating Control
The following example shows how heating behaves as Ta starts to fall:
- When Ta falls below +4 °C, heating is enabled.
- Heating keeps Th > +4 °C until Ta < -1 °C.
- Heating keeps Th > 0 °C until Ta < -15 °C.
When the heating function is disabled the heating is off in all conditions,
see Supervisor Message on page 123.
NOTE
Snow accumulation may cause a temporary wind measurement
problem even when the heating is enabled.
Vue de la page 31
1 2 ... 27 28 29 30 31 32 33 34 35 36 37 ... 170 171

Commentaires sur ces manuels

Pas de commentaire