Chapter 7 __________________________________________________ Getting the Data Messages
VAISALA______________________________________________________________________ 101
The structure of the pressure, temperature and humidity sensor response
message:
The structure of the precipitation sensor response message:
<cr><lf> = Response terminator
where
$ = Start of the message
WI = Device type (WI = weather instrument)
XDR = Transducer measurement response identifier
C = Transducer id 0 type (Temperature), see the
following Transducer table
23.3 = Transducer id 0 data (Temperature)
C = Transducer id 0 units (C, Temperature)
0 = Transducer id for Temperature
C = Transducer id 1 type (temperature)
23.3 = Transducer id 1 data (Tp internal temperature)
C = Transducer id 1 units (C, Tp internal temperature)
1 = Transducer id for Tp internal temperature
H = Transducer id 0 type (Humidity)
50.1 = Transducer id 0 data (Humidity)
P = Transducer id 0 units (%, Humidity)
0 = Transducer id for Humidity
P = Transducer id 0 type (Pressure)
1009.1 = Transducer id 0 data (Pressure)
H = Transducer id 0 units (hPa, Pressure)
0 = Transducer id for Pressure
* Checksum delimiter
75 = Two-character checksum for the response
<cr><lf> = Response terminator
where
$ = Start of the message