Getting Measurement Message
from Serial Line
Press R to start output of measurements. Press S, the Esc button or
reset the transmitter to stop outputting. See command SMODE to
change the default (power-up) operation mode.
Format the output by using the following commands:
- resulting interval can be changed with the command INTV.
- output string format can be changed with the command FORM.
- status of purge, sensor warming and autocalibration can be added
with the command FST.
- date and time information can be added with commands FDATE
and FTIME.
Example:
>r
Tdf=-20.6 'C H2O= 958 ppmV x= 0.6 g/kg
>r
Tdf=-20.7 'C H2O= 958 ppmV T= 23.8 'C RH= 3.3 %RH
>
To end the RUN mode issue the S command. After this, all other
commands can be used.
To output the reading once in STOP mode issue the SEND command.
If value is too long to fit to the allocated space or if there is an error in
outputting the quantity, value is displayed with stars ‘*’.
The output mode can be changed with the commands: FORM, FST,
FDATE, TIME.
TIME and DATE
You can format the serial line message by using the TIME and DATE
commands. To set time issue the TIME command. To set date issue
the DATE command.