BGC-FTIR Sensors | PTB 210 27
Operating Commands
To output one single pressure reading with two decimals (as used in the
programming of the weather station) use the command:
.P<cr>
For continous output of the pressure readings use the command:
.BP<cr>
The output depends on the measurement rate and the averaging setting (see
this section on page 26). Output is stopped by pressing the enter-key (<cr>).
To select a pressure unit use the command:
.UNIT.x<cr>
x unit x Unit
0 hPa (default) 6 kPa
1 mbar 7 Pa
2 inHg 8 mmH
2
O
3 psia 9 inH
2
O
4 torr 10 bar
5 mmHg
For output with the unit use the command:
.FORM.1<cr>
For output without the unit use the command:
.FORM.0<cr>
NOTE: Make sure to reset the barometer with the command .RESET<cr>
to activate the new settings. The settings can be checked with the
command ?<cr>.