User’s Guide ______________________________________________________________________
66 __________________________________________________________________ M210906EN-C
General Commands
In case the error messaging is disabled (see Supervisor Message on page
123), WXT520 does not return any response message with the general
commands given in ASCII and NMEA-formats.
Reset (aXZ)
This command is used to perform software reset on the device.
Command format in ASCII and NMEA 0183: aXZ<cr><lf>
Command format in SDI-12: aXZ!
The response depends on the communication protocol, see the
examples.
Example (ASCII):
0XZ<cr><lf>
0TX,Start-up<cr><lf>
Example (SDI-12):
0XZ!0<cr><lf> (=device address)
Example (NMEA 0183):
0XZ<cr><lf>
$WITXT,01,01,07,Start-up*29
where
a = Device address
XZ = Reset command
<cr><lf> = Command terminator in ASCII and NMEA 0183
! = Command terminator in SDI-12